24-Inch 117L Built-In Cigar Humidor with Precision Humidity Control

A 117L compressor cigar humidor with 65-75% humidity control, a 12-22°C temperature range and Spanish cedar storage for controlled cigar aging.

professional cigar humidor

Any questions or concerns?

Regarding product or factory information

professional cigar humidor

1. Product Positioning

This 24-inch cigar humidor is designed for built-in / freestanding use and provides 117 L of organized storage.

2. Temperature and Zones

The cabinet uses single climate zone temperature management with a stated range of 12-22°C.

3. Storage Interior

The interior includes 3 Spanish cedar shelves + cedar drawer to keep the collection organized and accessible.

4. Cooling and Air Management

Inverter compressor supports stable storage conditions. Lighting is listed as Interior LED.

5. Door and Installation

The cabinet features Full black glass door; reversible hinge and measures 595 x 570 x 820 mm, supporting built-in / freestanding placement.

6. Controls and Key Features

Key features include 65-75% RH; safety lock; front ventilation; UV shield. Stated noise information: Not stated.

其他信息

Commercial Refrigerator FAQ | Troubleshooting & Solutions

❄️ Commercial Freezer & Refrigerator FAQ

Common issues, expert troubleshooting, and practical solutions — keep your equipment running at peak performance.

🔧
Unit not cooling / poor temperature performance

Possible causes & solutions:

  • Power & connection – Verify plug is secure and circuit breaker is ON. Check if interior light works.
  • Condenser coils dirty – Clean coils (rear or bottom) every 3–6 months using a soft brush or vacuum.
  • Thermostat setting – Ensure setpoint is correct (e.g., 2~10℃ for chillers / -18℃ for freezers).
  • Overloaded unit – Avoid blocking air vents; leave space between items for airflow.
PRO TIP: Allow 24h after restocking for temperature to stabilize.
💧
Excessive frost or ice buildup

Why it happens & how to fix:

  • Door left open or door seal damaged – Inspect gasket for cracks/warping. Clean with warm water and test seal with paper sheet.
  • Frequent door openings – Train staff to minimise opening time, especially in humid conditions.
  • Defrost system failure – For fan‑cooled units, check defrost timer/heater. Manual defrost may be needed.
  • Improper temperature setting – Set to recommended level; too low increases frost formation.
⚠️ For heavy ice: turn off unit, remove products and allow natural thaw, then clean interior.
🔊
Unusual noise (loud hum, rattling, clicking)

Diagnose and resolve:

  • Leveling & contact – Ensure unit stands on even floor; adjust levelling feet. Avoid contact with walls or cabinets.
  • Loose components or fan blades – Check evaporator/condenser fan for debris or bent blades. Tighten mounting screws.
  • Compressor vibration – Verify compressor grommets are intact. Persistent heavy noise might indicate compressor wear.
  • Clicking sound – Could be start relay or overload protector. Contact service if repetitive clicking continues.
🎧 Normal sounds: refrigerant flow (slight bubbling) and occasional compressor hum are typical.
💨
Unit runs constantly / high energy consumption

Energy efficiency fixes:

  • Condenser coil maintenance – Dusty coils force compressor to work longer. Clean coils thoroughly.
  • Poor door sealing – Replace worn gasket; perform a dollar bill test (should not slide out easily).
  • Ambient temperature too high – Place unit away from heat sources (ovens, direct sunlight). Ensure adequate ventilation space.
  • Overstocking warm items – Cool products before placing inside. Allow airflow around the thermostat sensor.
📉 Save up to 15% energy by cleaning condenser coils monthly in heavy-use areas.
💦
Water leaking inside or on the floor

Stop water accumulation:

  • Clogged defrost drain line – Clean drain pan and use a pipe cleaner or hot water to flush the drain tube.
  • Door not closing properly – Adjust door alignment and clean gasket to avoid condensation overflow.
  • Frequent door opening in humidity – Install air curtains or reduce opening time; check that door closes tightly.
  • Cracked drain pan or misaligned tubing – Inspect pan for damage; replace if necessary.
🧼 Regularly clear drain hole with mild soap solution to prevent algae buildup.
🌡️
Temperature is inconsistent (warm spots or freezing food)

Stabilize internal climate:

  • Blocked air vents – Do not overpack. Rearrange products to allow even cold air circulation (especially in fan‑cooled units).
  • Faulty door gasket – Warm air infiltration creates zones. Replace gasket if cracked or brittle.
  • Sensor or thermostat malfunction – Test with external thermometer. Calibrate or replace sensor if deviation exceeds ±3°C.
  • Direct cooling units (static) – Avoid placing temperature-sensitive items directly against evaporator plate.
📏 Use a digital min/max thermometer to monitor overnight performance.
🧊
Ice maker / display not working (optional feature)

Troubleshoot ice production and lighting:

  • Check water supply line (ice maker models) – Ensure valve is open and line is not frozen. Replace filter if blocked.
  • LED interior light off – Check bulb or LED driver; simple replacement often solves. Ensure door switch is functional.
  • Digital display error code – Refer to manual. Power cycle (unplug 3 min) may reset temporary glitches.
  • Temperature too low for ice maker – Adjust freezer section temp to -12°C ~ -15°C for optimal ice production.
🔌 Keep spare lamps and door switches for quick service replacement.
⚙️
Compressor runs but no cooling / hot to touch

Critical checks for refrigeration circuit:

  • Refrigerant leak (R290/R600a systems) – If pipes have frost only at entry, suspect leak. Call certified technician for repair.
  • Start relay or overload failure – Intermittent cooling? Test relay with multimeter; replacement is affordable.
  • Condenser fan not running – Fan motor failure leads to compressor overheating. Replace fan motor immediately.
  • Blocked capillary tube – Usually requires professional service to clear or replace.
🚨 Never attempt to repair refrigerant circuit yourself — always use EPA/qualified technician.

Get a Free Quote

Tell us your requirements — our team responds within 24 hours

🏭 Factory Direct

📋 CE / ISO 9001

🌍 Export Ready

🔗 Product: AUTO-FILL
Loading product...
Loading product link...

🔐 Your information is safe. No spam, ever.